Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13654139

- Product Categories
- Friendly Links
Information Name: | S3 (T) -VD-3 trio voltage transmitter |
Published: | 2015-02-09 |
Validity: | 360 |
Specifications: | S3 (T) -VD-3 |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Overview S3 (T) -VD-3 transmitter is able to be measured by the AC voltage signal isolation amplifier, converting the input voltage into a DC voltage or current amount of the instrument is linearly proportional to the output, which is widely used in power systems and non-electrical systems, long-term continuous operation, realize the measurement of the amount of the AC voltage. Features S3 (T) -VD-3 Transmitter The series of high accuracy, good conversion performance, good temperature characteristics, have lightning protection. S3 (T) -VD-1T (N3-VD-1T), S3 (T) -VD-3T (N3-VD-3T) type transmitter, the input signal waveform distortion does not affect the measurement accuracy of the instrument. With a long-distance transmission capacity (4 ~ 20mA, 500Ω), fixed way, in line with DIN46277, according to the 35mm mounted on aluminum rails. S3 (T) -VD-3 transmitter specific issues Selection Model S3 (T): 0.2 级 N3: 0.5 class system 1: single-phase (average measured RMS statements) 1S: Single-phase dual output (average measurement, presentation RMS) 1S: single-phase (rms measurement) 3: Three-phase (average measured RMS statements) 3T: Three-phase (True RMS measurements) input signal range 1: 0 ~ 150V 4: 0 ~ 380V 6: 0 ~ 450V 2: 0 ~ 120V 5: 0 ~ 100V 0: Other 3: 0 ~ 300V 6: 0 ~ 220V input signal frequency 5: 50 ± 5Hz 6: 60 ± 5Hz 0: Other output range V1: 0 ~ 1V A1: 0 ~ 1 Ma 0: Other V2: 0 ~ 5V A2: 0 ~ 10 mA V3: 1 ~ 5V A3: 0 ~ 20 mA V4: 0 ~ 10V A4: 4 ~ 20 mA auxiliary power supply A: AC 110V D: DC 48V O: Other B: AC 220V E: DC110V C: DC 24V F: DC 220V structure: wiring diagram in Figure 01, 02: Single meet Figure A1 single-phase three-phase dual output shown in Figure A11 Figure A4 S3 (T) -VD-3 transmitter models and parameters to fill the sample: (1) N3-VD-1-55A4B 0.5 级 AC voltage transducer (average measured RMS statements) input signal range: 0 ~ 100V; the input signal frequency: 50 ± 5Hz; output range: 4 ~ 20mA; auxiliary power supply: AC220V. S3 (T) -VD-3 transmitter (2) S3 (T) -VD-3T-25V2E 0.2 级 phase AC voltage transducer (True RMS measurements) input signal range: 0 ~ 120V; frequency of the input signal : 50 ± 5Hz; output range: 0 ~ 5V; Auxiliary Power: DC110V. S3 (T) -VD-3 transmitter (3) N3-VD-1S-45V2A4B 0.5 Dual-stage single-phase output AC voltage transducer (average measured RMS statements) input signal range: 0 ~ 380V; input signal frequency: 50 ± 5Hz; output range: Ⅰ Road 0 ~ 5V, Ⅱ Road 4 ~ 20mA; S3 (T) -VD-3 transmitter |
Admin>>>
You are the 14036 visitor
Copyright © GuangDong ICP No. 10089450, Haiyan Jin Han Electronic Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 14036 visitor
Copyright © GuangDong ICP No. 10089450, Haiyan Jin Han Electronic Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility